AC Power Cord With Coiled Cable

AC Power Cord With Coiled Cable

Rated voltage: 230V, 250V
Rated current: 1A-10A
Wire core specifications: 0.75mm², 1.0mm², 1.5mm², 2.5mm², etc.
Length: customizable
Certification mark: CE certification, VDE certification

Cable length: The length is shorter in the curled state, which is convenient for storage. The length after stretching can generally reach about 3.8m - 4m, which can meet the connection requirements between electrical equipment and power sockets within a certain range.
Wire core specifications: Common ones are 2×0.75mm², 3×1.0mm², 3×1.5mm², etc. The wire core material is mostly high-purity oxygen-free copper, which has good conductivity and can effectively reduce the loss during power transmission.
Insulation and sheath material: The insulation material generally uses polyvinyl chloride (PVC) or cross-linked polyethylene (XLPE), which has good insulation and heat resistance. The sheath material has a variety of options such as PVC and polyurethane (PU). The sheath made of PU has better wear resistance, water resistance and flexibility.

AC Power Cord with Coiled Cable

 

Rollable design: convenient for storage and organization, space saving, easy to carry, suitable for electrical equipment that needs to be moved or relocated frequently.
Safe and reliable: passed CE, VDE and other relevant certifications, in line with European safety, quality and environmental standards.
Strong compatibility: designed according to European standards, the plug and socket interface conform to the European common standard specifications, CEE 7/7 standard.

-

European Coiled AC Power Cord Manufacturing Process

 

Material selection: wire core, insulation and sheath materials. For coiled AC power cords, the sheath material focuses on flexibility and elasticity to withstand repeated curling and stretching.

 

Copper and aluminum monofilament drawing: copper and aluminum rods are passed through a wire drawing machine at room temperature and through one or several die holes of a drawing die to reduce their cross-section, increase their length and increase their strength. Wire drawing is the first process in the production of wires and cables, and die matching technology is the key process parameter for wire drawing.

 

Monofilament annealing: copper and aluminum monofilaments are heated to a certain temperature, and the toughness of the monofilaments is increased and the strength of the monofilaments is reduced by recrystallization to meet the requirements of wires and cables for conductive cores. The key to the annealing process is to prevent copper wire oxidation.

 

Conductor twisting: In order to improve the flexibility of the power cord and facilitate laying and installation, the conductive core is made of multiple monofilaments twisted together. From the twisting method, it can be divided into regular twisting and irregular twisting, and irregular twisting can be divided into bundle twisting, concentric twisting, etc. In order to reduce the occupied area of ​​the wire and the geometric size of the power cord, the conductor will be compressed when twisting, so that the ordinary circle becomes a semicircle, fan-shaped, tile-shaped and compressed circle.

 

Insulation extrusion: Plastic power cords mainly use extruded solid insulation layer. The extrusion process requires the control of the eccentricity of the insulation thickness to ensure that the surface of the insulation layer is smooth, without roughness, burning, impurities and other problems. At the same time, the cross-section of the extruded insulation layer should be dense and solid, without pinholes and bubbles visible to the naked eye.

 

Cabling: The insulated wire cores are twisted together according to certain rules, including the process of filling the gaps between the wire cores during twisting and wrapping the cable core with tape. The technical requirement of cabling is to prevent the twisting of the cable caused by the turning over of the special-shaped insulated wire core and prevent the insulation layer from being scratched. Most cables will also complete the filling and binding processes during cabling to ensure the roundness and stability of the cable after cabling and ensure that the cable core is not loose.

 

Inner sheath production: In order to protect the insulated wire core from being scratched by the armor, the insulation layer needs to be properly protected. The inner sheath is divided into an extruded inner sheath (isolation sleeve) and a wrapped inner sheath (cushion), and the wrapped cushion can be carried out simultaneously with the armoring process.

 

Armoring (if necessary): For some power cords that need to withstand large external forces or special environments, armor layers such as steel belt armor or steel wire armor may be added to improve the mechanical strength and compressive resistance of the power cord. However, for general European AC power cords with coils, armor layers are rarely used because armor increases the hardness of the power cord and is not conducive to the curling and stretching of the coils.

 

Extrusion of outer sheath: According to different requirements for power cords, the plastic sheath is directly extruded by an extruder to form an outer sheath. For AC power cords with coils, the extrusion process of the outer sheath is more demanding, and it is necessary to ensure that the outer sheath has good flexibility and elasticity to adapt to the repeated stretching and bending of the coils. At the same time, the surface of the outer sheath should be smooth and free of defects to avoid wear on other parts during the curling process.

 

Plug installation: According to European standards, install a plug that meets the specifications on the power cord, such as the CEE 7/7 standard plug. The installation of the plug needs to ensure a firm connection and good contact to ensure a safe and reliable electrical connection. During the installation process, pay attention to the insulation treatment of the plug and the power cord to prevent the risk of leakage.

 

Wire winding processing: Usually a special wire winding equipment is used to wind the produced AC power cord into a specific shape and size. During the winding process, the winding tension and speed must be controlled to prevent the power cord from being excessively stretched, twisted or damaged. At the same time, the neatness and tightness of the winding must be ensured to facilitate users to smoothly stretch and retract the power cord when using it. Some high-quality winding AC power cords will also add an automatic wiring function to the winding device to make the power cord more neatly arranged when curling and reduce the possibility of mutual entanglement.

 

Testing and certification: During the production process and after the finished product is completed, the power cord will be subjected to various tests, including electrical performance tests (such as withstand voltage tests, insulation resistance tests, etc.), mechanical performance tests (such as tensile strength tests, bending tests, etc.) and appearance inspections. For AC power cords with coils, we also conduct coil performance tests, such as coil life tests, to verify the performance stability of the power cord under repeated coiling and stretching conditions. Our products can only be legally sold and used in the European market if they have passed relevant European certifications (such as CE, VDE, etc.).

Hot Tags: ac power cord with coiled cable, China, suppliers, manufacturers, factory, wholesale, cheap

Request a Quote

Save up to 40% on labor costs with bundled cable from One-Pull

Bundled cable solutions reduce labor costs and streamline job completion. Get a same-day quote here.

page-1-1

Email:

Jason_zheng@hongzhoucable.com

image

Mob:

+86-13511395441, +86-13511353441

image

Skype:
+86-13511395441, +86-13511353441

image

Wechat/WhatsApp:
+86-13511395441, +86-13511353441

Send Inquiry

(0/10)

clearall